Pentair UltraTemp 120R H/C Heat Pump 127/71K BTU Black - 460965
The Pentair UltraTemp 120 H/C pool heat pump, part 460965, provides both heating and cooling in a black, corrosion-resistant composite cabinet. A titanium heat exchanger and digital LCD controls support pool temperature management.
Heating and cooling performance
Pentair's 2025–2026 catalog lists the following performance for part 460965 under its 80/80/80 rating column: 80°F air temperature, 80% relative humidity and 80°F water temperature, rated in accordance with AHRI Standard 1160.
- Heating capacity: 125,000 BTU/h; coefficient of performance (COP): 5.5.
- Cooling capacity: 71,000 BTU/h; COP: 4.1.
- At 80°F air, 63% relative humidity and 80°F water: heating capacity of 118,000 BTU/h; COP of 5.3.
- At 50°F air, 63% relative humidity and 80°F water: heating capacity of 80,000 BTU/h; COP of 4.0.
Actual output depends on operating conditions. Heat pumps are intended to maintain pool temperature rather than provide the rapid heating response of a gas heater. Confirm the ratings on the supplied unit's nameplate and documentation, as older Pentair literature lists different figures.
Controls and construction
- A titanium heat exchanger provides corrosion resistance.
- LCD controls display menu-driven, full-word messages.
- AutoSet monitors water temperature and can turn the circulation pump on and off as needed to maintain the selected temperature.
- Automatic defrost senses refrigerant temperature to help prevent freezing.
- A thermostatic expansion valve (TXV) regulates refrigerant flow.
- The existing product specifications list a scroll compressor, R410A refrigerant and ETL listing.
- The black plastic composite cabinet resists pool chemicals and weather exposure.
Electrical and plumbing details
- Electrical supply: 230V, single phase, 60 Hz.
- Pentair catalog breaker size: 50A.
- Existing product specifications list minimum circuit ampacity of 42A and electrical input of 6.6 kW.
- Listed water flow range: 30–120 GPM.
- Listed water connection size: 2 inches.
Have your installer verify electrical requirements, plumbing, automation compatibility and installation clearances against the specific unit's nameplate and installation manual. Existing listed cabinet dimensions are 45-1/2 inches high, 38.9 inches wide and 33.8 inches deep; confirm dimensions for your supplied unit before planning placement.
Will this heat pump fit my pool?
Sizing depends on your pool and operating conditions. Use Pentair's sizing calculator and confirm the selection with your pool professional rather than relying on BTU capacity alone.
Pentair 2025–2026 heater and heat pump catalog | Earlier manufacturer brochure | Pentair heat pump sizing calculator
-